This GSM Pump Controller allows you to control and monitor your pump remotely using SMS commands or via a call (IVRS). Compatible with all GSM networks except Jio, this controller supports up to 9 registered mobile numbers. It is designed for efficient and secure motor control, featuring multiple operational modes, adjustable delay settings, and safety mechanisms like overload and underload protection.
Any make of preventer can use for above model
Note : In this Model we are using 3 phase preventer & Sequence checking seperate Box so as to avoid high voltage damages , If there is any High voltage or spikes only This unit will damage
Overview:
This GSM Pump Controller allows you to control and monitor your pump remotely using SMS commands or via a call (IVRS). Compatible with all GSM networks except Jio, this controller supports up to 9 registered mobile numbers. It is designed for efficient and secure motor control, featuring multiple operational modes, adjustable delay settings, and safety mechanisms like overload and underload protection.
Key Features:
Control via SMS:
- Send commands from registered mobile numbers.
- Store up to 9 mobile numbers for operation.
- Easy setup with a variety of commands for flexible functionality.
IVRS Functionality:
- Control pump using a call with voice guidance.
- Supports commands for pump ON/OFF, mode selection, and status retrieval.
Power Specifications:
- Operating Voltage: 12VAC/DC, 2 Amps.
- Relay Load: 230VAC, 5 Amps.
Modes of Operation:
- Mode 1: Relay ON for 5 seconds (adjustable delay via command
#DLY=xx
), with preventer enabled. - Mode 2: Relay ON for 5 seconds (adjustable delay via
#DLY=xx
), with preventer disabled. - Mode 3: Continuous relay ON with preventer enabled.
- Mode 4: Continuous relay ON with preventer disabled.
- Mode 1: Relay ON for 5 seconds (adjustable delay via command
Timer Functionality:
- Schedule pump operation for a specific duration.
- Example: Turn pump ON for 1 hour with the command
#MTA=60
(time in minutes).
Safety Features:
- Underload Protection: Monitors load below
#UL=xx
(0–60 amps). - Overload Protection: Monitors load above
#OL=xx
(0–60 amps). - Delay for Load protection triggers adjustable via
#DRY=xx
(default: 60 seconds).
- Underload Protection: Monitors load below
Auto Mode:
- Automatically switches ON the pump after power restoration.
- Delay can be adjusted using
#AUTO=xx
(0–999 seconds).
Preventer Check:
- Delay for preventer failure adjustable with
#PRD=xx
(0–99 seconds). - If the preventer is faulty, the motor will not start.
- If Preventer delay is 0 > if preventer fail > Motor will start
- Delay for preventer failure adjustable with
Phone Number Management: ( Master NO Only recives - Power On / Failure messages )
- Add numbers with commands
#1STNxxxxxxxxxx
to#9STNxxxxxxxxxx
. - Store only master number using
#C
. = #1STNxxxxxxxxxxx ( #C AND #1STNxxxxxxxxxxx Both commands store in ID1 as master NO ) - View stored numbers with
#SPN
.
- Add numbers with commands
SMS Commands:
Command | Function |
---|---|
#1 | Pump ON. |
#2 | Pump OFF. |
#3 | Auto mode ON. |
#4 | Auto mode OFF. |
#5 | Mode 1: Relay ON for 5 seconds (adjustable delay via #DLY=xx ). |
#6 | Mode 2: Relay ON for 5 seconds, preventer disabled. |
#7 | Retrieve status of the product. |
#8 | Mode 3: Continuous relay ON with preventer enabled. |
#9 | Mode 4: Continuous relay ON with preventer disabled. |
#MTA=xx | Set motor ON duration (in minutes). |
#UL=xx | Set underload threshold (0–60 amps). |
#OL=xx | Set overload threshold (0–60 amps). |
#DRY=xx | Set delay for under/overload protection (0–999 seconds). |
#AUTO=xx | Set auto mode delay after power restoration (0–999 seconds). |
#PRD=xx | Set preventer check delay (0–99 seconds). |
#SPN | View stored phone numbers. |
IVRS Commands (Call Functionality):
Dial Commands:
1
: Pump ON.2
: Pump OFF.3
: Auto mode ON.4
: Auto mode OFF.5
: Mode 1: Relay ON for 5 seconds, preventer enabled.6
: Mode 2: Relay ON for 5 seconds, preventer disabled.7
: Retrieve status (voice feedback).
After operation, the call will automatically disconnect with a voice feedback confirmation.
Usage Instructions:
- Insert a GSM SIM card (excluding Jio) into the controller.
- Send SMS commands from any registered mobile number.
- For IVRS mode, call the controller's number and follow voice prompts.
Applications:
- Agricultural motor control.
- Residential water pump systems.
- Industrial motor automation.
Package Includes:
- GSM Pump Controller Unit.
- User Manual.
- Quick Installation Guide.
Specification
- Input power Supply 12 VAC/ DC - 2 amps
- Easy SMS based Commands
- Just 1 Missed call to On or OFF Motor
- Store upto 9 Mobile Nos
- Any damage due to wrong conncetion , high voltage spikes warranty cant be claimed , only service charges will be FREE
- If anything found in Manufacturing defects Board will be Replaced
Demo Video for Only latest Version V3.0
HOW TO CONNECT GSM CONTROL WITH STARTER DEMO VIDEO
How to connect regular starters using
This GSM Based Motor Control will control only START and STOP Buttons , Motor Load Will be on Contacter in Starter Itself , So we are not Disturbing Any circuits in Starters Except STOP button should be connected in series with STOP Relay as show ABOVE VIDEO
NOTE : THIS PRODUCT DESIGNED FOR INDIA ONLY ( CODE +91
ONLY )- FOR OTHER COUNTRIES PRODUCT WILL NOT RESPOND, WE WILL DO
ALTERATION ON REQUEST
GSM Motor Control with 3 P& Preventer
- Product Code: GSMM2
- Availability: In Stock
-
Rs2,500.00